Standby Generator- 20 kW
|
GENERATOR |
Model 05506 (20 kW) |
|
Rated Maximum Continuous Power Capacity (LP) |
20,000 Watts* |
|
Rated Maximum Continuous Power Capacity (NG) |
18,000 Watts* |
|
Rated Voltage |
120/240 |
|
Rated Maximum Continuous Load Current 120 Volts 240 Volts |
166.6 LP/150 NG 83.3 LP/75 NG |
|
Total Harmonic Distortion |
Less than 5% |
|
Main Line Circuit Breaker |
100 Amp |
|
Phase |
1 |
|
Number of Rotor Poles |
2 |
|
Rated AC Frequency |
60Hz |
|
Power Factor |
1 |
|
Battery Requirement (not included) |
Group 26 12 Volts and 525 Cold-cranking Amperes Minimum |
|
Unit Weight |
451 Pounds |
|
Dimensions (L” x W” x H”) |
48 x 25 x 29 |
|
Sound output in dB(A) at 23 ft. with generator operating at normal load |
66 |
|
Sound output in dB(A) at 23 ft. with generator in Whisper-Test™ low speed exercise mode |
60 |
|
ENGINE |
Model 05506 (20 kW) |
|
Type of Engine |
GENERAC OHVI V-TWIN |
|
Number of Cylinders |
2 |
|
Rated Horsepower |
36 @ 3,600 rpm |
|
Displacement |
999cc |
|
Cylinder Block |
Aluminum w/Cast Iron Sleeve |
|
Valve Arrangement |
Overhead Valve |
|
Ignition System |
Solid-state w/Magneto |
|
Governor System |
Electronic |
|
Compression Ratio |
9.5:1 |
|
Starter |
12 Vdc |
|
Oil Capacity Including Filter |
Approx. 1.7 Qts. |
|
Operating RPM |
3,600 |
|
Fuel Consumption Natural Gas cu.ft./hr. 1/2 Load Full Load Liquid Propane ft3/hr (gal/hr) 1/2 Load Full Load |
206 294 69 (1.89) 106 (2.90) |
|
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 11 to 14 inches of water column for LP gas |
|
|
CONTROLS |
|
|
2-Line Plain Text LCD Display |
Simple user interface for ease of operation |
|
Mode Switch -Auto |
Automatic Start on Utility failure. 7 day exerciser |
|
-Off |
Stops unit. Power is removed. Control and charger still operate. |
|
-Manual/Test (start) |
Start with starter control, unit stays on. If utility fails, transfer to load takes place. |
|
Engine Start Sequence |
Cyclic cranking: 7 sec. on, 7 rest (90 sec. maximum duration) |
|
Engine Warm-up |
10 seconds |
|
Engine Cool-Down |
1 minute |
|
Starter Lock-out |
Starter cannot re-engage until 5 sec. after engine has stopped. |
|
2.5 Amp Timed Trickle Battery Charger |
Standard |
|
Automatic Voltage Regulator w/Overvoltage Protection |
Standard |
|
Automatic Low Oil Pressure Shutdown |
Standard |
|
Overspeed Shutdown |
Standard, 72Hz |
|
High Temperature Shutdown |
Standard |
|
Overcrank Protection |
Standard |
|
Safety Fuse |
Standard |
Standby Generator- 20 kW
|
TRANSFER SWITCH & PRIORITY LOAD CENTER |
Model 05506 (20 kW) |
|
No. of Poles |
2 |
|
Current Rating (amps) |
200 |
|
Voltage Rating (VAC) |
250 |
|
Utility Voltage Monitor (fixed) -Pick-up -Dropout |
75% 65% |
|
Return to Utility |
approx. 13 sec. |
|
Exerciser weekly for 12 minutes |
Standard |
|
UL Listed |
Standard |
|
Dimensions (H” x W” x D”) |
42 x 20 x 7.25 |
|
Total of Pre-wired Circuits in Priority Load Center No. 15A 120V No. 20A 120V No. 20A 240V No. 40A 240V No. 50A 240V |
16 5 5 1 1 1 |
|
Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts |
22,000 |
Transfer Switch Features
• Service Entrance Rated
• Load Shedding Capability
• Electrically operated,
mechanically-held contacts for fast, positive connections.
• Rated for all classes of load, 100% equipment rated, both inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA 3R (Outdoor rated)
enclosure is standard on the
200 amp switch.
Double D Electrical, Inc.